There is no pressure and temperature relief valve needed unless required by code saving time and money on installation.
Chronomite water heater installation.
If you increase the flow rate of the water above 5 gpm the water temperature will become cooler.
Heating coils are nichrome.
The flow switch activates at 4 gallons per minute gpm and deactivates at 35 gallons per minute gpm.
Allowing air into the heater be sure to follow the following start up procedure.
Failure to comply with code requirements voids the warranty.
Chronomite instant flow compliant mix low activation models are manufactured to provide reliable point of use hot water.
Chronomite instant flow micro low flow 0 35 gpm point of use electric tankless water heater 20 amp 277 volt 5540 watt 110 f model m20l 277110f i 245 85.
Housing is fabricated from rugged cast aluminum alloy.
By heating water instantaneously chronomite electric tankless water heaters offer water energy savings resulting in lower maintenance operational costs.
Turn the hot water fixture to activate the flow switch.
Local plumbing and electrical codes must be followed in the installation of this water heater and it s accessories.
Expel all air from lines and heater.
Point of use mini tank point of use tankless point of use high capacity and omni flow control products.
Turn on electrical power supply close circuit breaker.
Figure 1 heater installation.
If installed in a vertical position you will risk a burn out of the heating coils and the heater will not be covered under the warranty.
Turn off electrical supply open circuit breaker.
Chronomite tankless water heaters are designed for a horizontal installation.
Turn on water supply.